HAIRF Module Data Center
Hairf Modular Date Center also knows as “HMDC”, according to the global trend of cloud computing and development needs adhering to the efficient modular construction concept the integration of Internet based on traditional modular digital technology. HMDC is a smart and flexible architecture suitable for small and medium enterprise applications. In addition to the integration of main systems of power, cooling, racks and monitoring, the cold or hot aisle containment also provides superior air flow management to enhance cooling efficiency. A traditional datacenter takes 18 to 24 months to build, while a modular datacenter requires only a few weeks or months for deployment. Hairf modular datacenter, with its fully modular design concept, is flexible and offers pay-as-you-grow with short installation time to meet the rapidly growing needs of data storage and processing.
Description
Model |
HMDC-0803 |
HMDC-0805 |
HMDC-0808 |
HMDC-1603 |
HMDC-1605 |
HMDC-1608 |
HMDC-2403 |
HMDC-2405 |
HMDC-2408 |
Cabinet subsystem |
|||||||||
Dimension |
W*D*H:600*1100*2000mm,Other sizes can be customized |
||||||||
Quantity |
8 units |
16 units |
24 units |
||||||
Cabinet Power density |
3kw/rack |
3kw/rack |
8kw/rack |
3kw/rack |
5kw/rack |
8kw/rack |
3kw/rack |
5kw/rack |
8kw/rack |
Cabinet Total power |
24KW |
40KW |
64KW |
48KW |
80KW |
128KW |
72KW |
120KW |
192KW |
Cabinet power supply |
Dual PDU power supply | ||||||||
Distribution subsystem |
|||||||||
Power supply |
2N power supply,Tier I grade | ||||||||
Column counter |
Precision column cabinet: double loop power supply | ||||||||
UPS |
Modular UPS |
||||||||
Model |
X7-50 |
X7-75 |
X7-100 |
X7-75 |
X7-100 |
X7-150 |
X7-100 |
X7-150 |
X7-250 |
Capacity |
50kVA |
75kVA |
100kVA |
75kVA |
100kVA |
150kVA |
100nVA |
150kVA |
250nVA |
Configuration |
2 sets |
2 sets |
2 sets |
2 sets |
2 sets |
2 sets |
2 sets |
2 sets |
2 sets |
Redundant architecture |
2(N+1) |
2(N+1) |
2(N+1) |
2(N+1) |
2(N+1) |
2(N+1) |
2(N+1) |
2(N+1) |
2(N+2) |
Refrigeration subsystem |
|||||||||
PAC |
In-row air conditioner | ||||||||
Model |
R261A |
R401A |
R261A |
R161A |
R261A |
R261A |
R261A |
R261A |
R401A |
Air supply |
Horizontal air supply | ||||||||
Cooling method |
Air-cooled/water-cooed/chilled water | ||||||||
Cooling capacity |
25.5kW |
41.5KW |
25.5KW |
15.5KW |
25.5KW |
25.5KW |
25.5KW |
25.5KW |
41.5KW |
Configuration |
2 pcs |
2 pcs |
4 pcs |
4 pcs |
4 pcs |
6 pcs |
4 pcs |
6 pcs |
6 pcs |
Redundant architecture |
1+1 redundancy |
1+1 redundancy |
3+1 redundancy |
3+1 redundancy |
3+1 redundancy |
5+1 redundancy |
3+1 redundancy |
5+1 redundancy |
5+1 redundancy |
Monitoring subsystem |
|||||||||
Terminal interface |
21 inch human touch screen | ||||||||
UPS monitoring |
Support | ||||||||
Battery Online monitoring |
Support(optional) | ||||||||
Power distribution monitoring |
Support | ||||||||
PAC monitoring |
Support | ||||||||
Leakage monitoring |
Support | ||||||||
Temperature and humidity monitoring |
Support | ||||||||
Smoke monitoring |
Support,Credit card/password/fingerprint(optional) |
||||||||
CCTV |
Support | ||||||||
Access control |
Support | ||||||||
   System status |
|||||||||
Size*W |
5.1*3.4m |
5.4*3.4m |
5.4*3.4m |
7.8*3.4m |
7.8*3.4m |
8.1*3.4m |
10.2*3.4m |
10.5*3.4m |
12*3.4m |
Area |
17.34m2 |
18.36m2 |
18.36m2 |
26.52m2 |
26.52m2 |
27.54m2 |
34.68m2 |
35.7m2 |
40.8m2 |