Description
Character and Advantage
● Support LBS synchronic control;
● Intelligent Fan speed regulation function;
● Support bypass maintenance(three phase input single phase output) ;
● LCD display function,user friendly display interface;
● Three-stage extensible charging design to ensure a more remarkable performance of the Batteries;
● Support parallel operation of more than 3 machines with shared battery packs;
● Support DC cold starting;without utility, the load can keep operating with the power offered by Batteries;
● Powerful charging function is convenient to extensive the capacity of standby batteries.Intelligent charging mode even extending battery life to cut down expenditures.
● Support automatic restart function: when utility goes normal after UPS is shutdown under battery mode,UPS can automatic restart;
● Good technical indicators: the approximate 1 input power factor,largely decreased the pollution to utility grid and improved the use ratio of grid,so X2 series UPS are real eco-type Power;
● Support mold proofing, moisture proofing and salt spray fog proofing, in order to decrease pollution to the mains power grid and improving the utilization rate of the grid is a real green and environmentally friendly power source;
● The product has flame retardant environmental protection function.
Model |
X2-1101(L) |
X2-1102(L) |
X2-1103(L) |
X2-1106(L) |
X2-1110(L) |
||||||
Capacity |
1kVA/0.8kW |
2kVA/1.6kW |
3kVA/2.4kW |
6kVA/4.8kW |
10kVA/8kW |
||||||
Input |
|||||||||||
Connection Model |
Single Phase+Ground |
||||||||||
Input Voltage |
200/208/220/230/240VAC |
||||||||||
Voltage Range |
110-300VAC |
||||||||||
Frequency range |
40~70Hz |
||||||||||
Power factor |
≥0.99 |
||||||||||
Output |
|||||||||||
Output Voltage |
200/208/220/230/240VAC |
||||||||||
Voltage regulation |
±1% |
||||||||||
Frequency |
Synchronous |
46-54Hz/56-64Hz |
|||||||||
Battery Model |
50Hz±0.1Hz/60Hz±0.1Hz |
||||||||||
Distortion(THDU) |
≤3% |
||||||||||
Peak Coefficient |
≥3:1 |
||||||||||
Overload Capacity |
110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min. |
||||||||||
Time switching |
Electric city/battery |
0ms |
|||||||||
Inverter/Bypass |
<4ms(standard environment) |
0ms |
|||||||||
Battery |
|||||||||||
Standard marching |
Battery Cells |
2 |
4 |
6 |
16(16-20 optional) |
||||||
Charging Current |
1.0A(Max) |
2.0A(Max) |
|||||||||
Battery Model |
12V ,9Ah |
||||||||||
Long lasting |
Battery Cells |
3 |
6 |
8 |
16(16-20 optional) |
||||||
Charging Current |
1A/2A/4A/6A settable |
||||||||||
Battery Model |
Depends on the applicant |
||||||||||
Efficiency |
|||||||||||
City Electricity Model |
≥91% |
≥93% |
|||||||||
Battery Model |
≥91% |
≥93% |
|||||||||
Display Interface |
|||||||||||
LCD/LED |
Loading Size,Battery Capacity,City Electricity Mode,Bypass Mode,Fault indication |
||||||||||
Control Management |
|||||||||||
Intelligent RS-232/USB |
Support Windows 2000/2003/XP/Vista/2008、Window7/8、Linux、Unit and MAC |
||||||||||
Option SNMP |
Support SNMP Internet Management |
||||||||||
Environment |
|||||||||||
Temperature |
0-40℃ | ||||||||||
Relative Humidity |
0-95%(Non Condensing) |
||||||||||
Noise |
<50dB@1m |
<55dB@1m |
<58dB@1m |
||||||||
Physical Character |
|||||||||||
Standard marching |
Size:Width*Depth*Height(mm) |
145*282*220 |
145*397*220 |
190*421*318 |
190*369*688 |
190*442*688 |
|||||
Net Weight(kg) |
11 |
18 |
29 |
62 |
67 |
||||||
Long lasting |
Size:Width*Depth*Height(mm) |
145*282*220 |
145*397*220 |
190*369*318 |
190*442*318 |
||||||
Net Weight(kg) |
6 |
8 |
9 |
13 |
17 |
Model |
X2-3310L |
X2-3115L |
X2-3120L |
X2-3130L |
||
Capacity |
10kVA/8kW |
15kVA/12kW |
20kVA/16kW |
30kVA/24kW |
||
Input |
||||||
Connection Model |
Three-phase+four wire |
|||||
Rate Voltage |
380/400/415VAC |
|||||
Voltage Range |
285-520VAC@100%Load;176-520VAC@50%Load |
|||||
Frequency range |
40-70HZ |
|||||
Power factor |
≥0.99 |
|||||
Output |
||||||
Output Voltage |
200/208/220/230/240VAC |
|||||
Voltage regulation |
±1% |
|||||
Frequency |
Synchronous |
46-54Hz/56-64Hz |
||||
Battery Model |
50Hz±0.1Hz/60Hz±0.1Hz |
|||||
Distortion(THDU) |
≤2%(Linear load)≤3%(Non-liner load) |
|||||
Peak Coefficient |
≥3:1 |
|||||
Overload Capacity |
110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min. |
|||||
Time switching |
Electric city/battery |
0ms |
||||
Inverter/Bypass |
0ms |
|||||
Battery |
||||||
Battery Cells |
16(16-20 optional) |
20(18-20 optional) |
||||
Charging Current |
1A/2A/4A/6A Settable |
|||||
Battery Model |
Depends on the applicant |
|||||
Efficiency |
||||||
City Electricity Model |
≥93% |
|||||
Display Interface |
||||||
LCD/LED |
Loading Size,Battery Capacity,City Electricity Mode,Bypass Mode,Fault indication |
|||||
Control Management |
||||||
Intelligent RS-232/USB |
Support Windows 2000/2003/XP/Vista/2008、Window7/8、Linux、Unit and MAC |
|||||
Option SNMP |
Support SNMP Internet Management |
|||||
Environment |
||||||
Temperature |
0-40℃ |
|||||
Relative Humidity |
0-95%(Non Condensing) |
|||||
Noise |
<58dB@1m |
<60dB@1m |
||||
Physical Character |
||||||
Size:Width*Depth*Height(mm) |
190*442*318 |
190*575*318 |
250*815*826 |
|||
Net Weight(kg) |
16 |
22 |
62 |
Model |
X2-3310L |
X2-3320L |
X2-3330L |
X2-3340L |
|
Capacity |
10kVA/8kW |
20kVA/16kW |
30kVA/24kW |
40kVA/36kW |
|
Input |
|||||
Connection Model |
Three-phase+four wire |
||||
Rate Voltage |
380/400/415VAC |
||||
Voltage Range |
285-520VAC@100%Load;176-520VAC@50%Load |
||||
Frequency range |
40-70HZ |
||||
Power factor |
≥0.99 |
||||
Output |
|||||
Output Voltage |
380/400/415VAC |
||||
Voltage regulation |
±1% |
||||
Frequency |
Synchronous |
46-54Hz/56-64Hz |
|||
Battery Model |
50Hz±0.1Hz/60Hz±0.1Hz |
||||
Distortion(THDU) |
≤2% |
||||
Peak Coefficient |
≥3:1 |
||||
Overload Capacity |
110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min. |
||||
Time switching |
0ms |
||||
Battery |
|||||
Battery Cells |
20(16-20 optional) |
32 |
|||
Charging Current |
4.0A Max |
12.0A Max |
|||
Battery Model |
Depends on the applicant |
||||
Efficiency |
|||||
City Electricity Model |
≥91% |
≥93% |
|||
Battery Model |
≥91% |
≥93% |
|||
Display Interface |
|||||
LCD/LED |
Loading Size,Battery Capacity,City Electricity Mode,Bypass Mode,Fault indication |
||||
Control Management |
|||||
Intelligent RS-232/USB |
Support Windows 2000/2003/XP/Vista/2008、Window7/8、Linux、Unit and MAC |
||||
Option SNMP |
Support SNMP Internet Management |
||||
Environment |
|||||
Temperature |
0-40℃ |
||||
Relative Humidity |
0-95%(Non Condensing) |
||||
Noise |
<60dB |
||||
Physical Character |
|||||
Size:Width*Depth*Height(mm) |
250*592*826 |
250*815*826 |
370*780*1000 |
||
Net Weight(kg) |
38 |
40 |
65 |
60 |
Rating & Review
There are no reviews yet.