X2 Series Ups

28 people are viewing this right now

Description

Character and Advantage

● Support LBS synchronic control;

● Intelligent Fan speed regulation function;

● Support bypass maintenance(three phase input single phase output) ;

● LCD display function,user friendly display interface;

● Three-stage extensible charging design to ensure a more remarkable performance of the Batteries;

● Support parallel operation of more than 3 machines with shared battery packs;

● Support DC cold starting;without utility, the load can keep operating with the power offered by Batteries;

● Powerful charging function is convenient to extensive the capacity of standby batteries.Intelligent charging mode even extending battery life to cut down expenditures.

● Support automatic restart function: when utility goes normal after UPS is shutdown under battery mode,UPS can automatic restart;

● Good technical indicators: the approximate 1 input power factor,largely decreased the pollution to utility grid and improved the use ratio of grid,so X2 series UPS are real eco-type Power;

● Support mold proofing, moisture proofing and salt spray fog proofing, in order to decrease pollution to the mains power grid and improving the utilization rate of the grid is a real green and environmentally friendly power source;

● The product has flame retardant environmental protection function.

 

Model

X2-1101(L)

X2-1102(L)

X2-1103(L)

X2-1106(L)

X2-1110(L)

Capacity

1kVA/0.8kW

2kVA/1.6kW

3kVA/2.4kW

6kVA/4.8kW

10kVA/8kW

Input

Connection Model

Single Phase+Ground

Input Voltage

200/208/220/230/240VAC

Voltage Range

110-300VAC

Frequency range

40~70Hz

Power factor

≥0.99

Output

Output Voltage

200/208/220/230/240VAC

Voltage regulation

±1%

Frequency

Synchronous
Correction range

46-54Hz/56-64Hz

Battery Model

50Hz±0.1Hz/60Hz±0.1Hz

Distortion(THDU)

≤3%

Peak Coefficient

≥3:1

Overload Capacity

110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min.

Time switching

Electric city/battery

0ms

Inverter/Bypass

<4ms(standard environment)

0ms

Battery

Standard marching

Battery Cells

2

4

6

16(16-20 optional)

Charging Current

1.0A(Max)

2.0A(Max)

Battery Model

12V ,9Ah

Long lasting

Battery Cells

3

6

8

16(16-20 optional)

Charging Current

1A/2A/4A/6A settable

Battery Model

Depends on the applicant

Efficiency

City Electricity Model

≥91%

≥93%

Battery Model

≥91%

≥93%

Display Interface

LCD/LED

Loading Size,Battery Capacity,City Electricity Mode,Bypass Mode,Fault indication

Control Management

Intelligent RS-232/USB

Support Windows 2000/2003/XP/Vista/2008、Window7/8、Linux、Unit and MAC

Option SNMP

Support SNMP Internet Management

Environment

Temperature

0-40℃

Relative Humidity

0-95%(Non Condensing)

Noise

<50dB@1m

<55dB@1m

<58dB@1m

Physical Character

Standard marching

Size:Width*Depth*Height(mm)

145*282*220

145*397*220

190*421*318

190*369*688

190*442*688

Net Weight(kg)

11

18

29

62

67

Long lasting

Size:Width*Depth*Height(mm)

145*282*220

145*397*220

190*369*318

190*442*318

Net Weight(kg)

6

8

9

13

17

 

Model

X2-3310L

X2-3115L

X2-3120L

X2-3130L

Capacity

10kVA/8kW

15kVA/12kW

20kVA/16kW

30kVA/24kW

Input

Connection Model

Three-phase+four wire

Rate Voltage

380/400/415VAC

Voltage Range

285-520VAC@100%Load;176-520VAC@50%Load

Frequency range

40-70HZ

Power factor

≥0.99

Output

Output Voltage

200/208/220/230/240VAC

Voltage regulation

±1%

Frequency

Synchronous
Correction range

46-54Hz/56-64Hz

Battery Model

50Hz±0.1Hz/60Hz±0.1Hz

Distortion(THDU)

≤2%(Linear load)≤3%(Non-liner load)

Peak Coefficient

≥3:1

Overload Capacity

110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min.

Time switching

Electric city/battery

0ms

Inverter/Bypass

0ms

Battery

Battery Cells

16(16-20 optional)

20(18-20 optional)

Charging Current

1A/2A/4A/6A Settable

Battery Model

Depends on the applicant

Efficiency

City Electricity Model

≥93%

Display Interface

LCD/LED

Loading Size,Battery Capacity,City Electricity Mode,Bypass Mode,Fault indication

Control Management

Intelligent RS-232/USB

Support Windows 2000/2003/XP/Vista/2008、Window7/8、Linux、Unit and MAC

Option SNMP

Support SNMP Internet Management

Environment

Temperature

0-40℃

Relative Humidity

0-95%(Non Condensing)

Noise

<58dB@1m

<60dB@1m

Physical Character

Size:Width*Depth*Height(mm)

190*442*318

190*575*318

250*815*826

Net Weight(kg)

16

22

62

 

Model

X2-3310L

X2-3320L

X2-3330L

X2-3340L

Capacity

10kVA/8kW

20kVA/16kW

30kVA/24kW

40kVA/36kW

Input

Connection Model

Three-phase+four wire

Rate Voltage

380/400/415VAC

Voltage Range

285-520VAC@100%Load;176-520VAC@50%Load

Frequency range

40-70HZ

Power factor

≥0.99

Output

Output Voltage

380/400/415VAC

Voltage regulation

±1%

Frequency

Synchronous
Correction range

46-54Hz/56-64Hz

Battery Model

50Hz±0.1Hz/60Hz±0.1Hz

Distortion(THDU)

≤2%

Peak Coefficient

≥3:1

Overload Capacity

110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min.

Time switching

0ms

Battery

Battery Cells

20(16-20 optional)

32

Charging Current

4.0A Max

12.0A Max

Battery Model

Depends on the applicant

Efficiency

City Electricity Model

≥91%

≥93%

Battery Model

≥91%

≥93%

Display Interface

LCD/LED

Loading Size,Battery Capacity,City Electricity Mode,Bypass Mode,Fault indication

Control Management

Intelligent RS-232/USB

Support Windows 2000/2003/XP/Vista/2008、Window7/8、Linux、Unit and MAC

Option SNMP

Support SNMP Internet Management

Environment

Temperature

0-40℃

Relative Humidity

0-95%(Non Condensing)

Noise

<60dB

Physical Character

Size:Width*Depth*Height(mm)

250*592*826

250*815*826

370*780*1000

Net Weight(kg)

38

40

65

60

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.